1. Poor heat dissipation due to environmental factors of the outdoor unit. Solution: Re-move the unit.


2. The outdoor unit is facing the wrong direction and is exposed to the sun for a long time. Solution: Reinstall it to a suitable place or install a sunshade.


3. The outdoor condenser is too dusty and dirty. Solution: Use a special air conditioner fin cleaner to clean the condenser.


4. The outdoor unit has poor heat dissipation, the fan is damaged and does not rotate or the speed is slow, and the fan capacitor has insufficient capacity or is damaged. Solution: Replace the fan and replace the capacitor.


5. The compressor start capacitor fails or has insufficient capacity, and the compressor fails to start. Solution: Replace the compressor start capacitor.


6. The compressor overheat protection device is damaged. Solution: Replace the compressor overheat protector.


7. Problems with the compressor itself, cylinder jam, coil burnout, etc. Solution: Replace the compressor.


8. Problems with refrigerant, too much or too little, the compressor overheats during long-term operation. Solution: Check the refrigerant pressure value and control it to the normal range.


9. System blockage, ice blockage, dirt blockage, etc. Treatment method: Clean the refrigeration system, vacuum and replace the refrigerant.